1.
Polymers (Basel) ; 16(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38475318

RESUMO

In this research, a molecularly imprinted polymer (MIP) was synthesized by precipitation polymerization using oxazepam (OZ) as a template molecule and was subsequently applied as a selective sorbent for the extraction of diazepam (DZP) and its metabolites in urine samples using an SPE cartridge. OZ, temazepam (TZ), nordiazepam (NZ) and DZP were analyzed in the final extracts by high-performance liquid chromatography with diode array detection (HPLC-DAD). The SPE extraction steps were optimized, and the evaluation of an imprinting factor was carried out. The selectivity of the method for OZ versus structurally related benzodiazepines (BZDs), such as bromazepam (BRZ), tetrazepam (TTZ) and halazepam (HZ), was investigated. Under the optimum conditions, the proposed methodology provided good linearity in the range of 10-1500 ng/mL, with limit of detection values between 13.5 and 21.1 ng/mL and recovery levels for DZP and its metabolites from 89.0 to 93.9% (RSD ≤ 8%) at a concentration level of 1000 ng/mL. The proposed method exhibited good selectivity, precision and accuracy and was applied to the analysis of urine samples from a real case of DZP intake.

2.
Foods ; 13(3)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38338548

RESUMO

Microplastics (MPs) and nanoplastics (NPs) are widely spread in the environment, generating significant concern due to their potential impact on environmental health. Marine species usually ingest plastic fragments, mistaking them for food. Many toxic compounds, such as plastic additives that are not chemically bound to the plastic matrix, can be released from MPs and NPs and reach humans via the food chain. This paper highlights the development and validation of a straightforward solid-liquid extraction clean-up procedure in combination with a matrix solid-phase dispersion method using high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS) detection, enabling facile, precise, and reliable identification and quantitation of a total of six bisphenols and phthalates in gilthead sea breams. Under the optimized conditions, the developed method showed good linearity (R2 > 0.993) for all target compounds. The recoveries obtained were between 70 and 92%. The relative standard deviations (RSDs) for reproducibility (inter-day) and repeatability (intra-day) were less than 9% and 10%, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for the target compounds ranged from 0.11 to 0.68 µg/kg and from 0.37 to 2.28 µg/kg, respectively. A new, efficient extraction methodology for the determination of BPA, BPS, BPF, DBP, DEP, and DHEP in gilthead seabream has been optimized and validated.

3.
Polymers (Basel) ; 15(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37959993

RESUMO

This paper describes a new methodology for carrying out quantitative extraction of cloxacillin from drinking and river water samples using a molecularly imprinted polymer (MIP) as a selective sorbent for solid-phase extraction (MISPE). Several polymers were synthesized via thermal polymerization using cloxacillin as a template, methacrylic acid (MAA) as a functional monomer, ethyleneglycoldimethacrylate (EGDMA) as a cross-linker and different solvents as porogens. Binding characteristics of the adequate molecularly imprinted and non-imprinted (NIP) polymers were evaluated via batch adsorption assays following the Langmuir and Freundlich isotherms and Scatchard assays. The parameters related to the extraction approach were studied to select the most appropriate polymer for cloxacillin determination. Using the optimized MIP as the SPE sorbent, a simple sample treatment methodology was combined with high-performance liquid chromatography (HPLC) to analyze cloxacillin residues in drinking and river water. Under the optimum experimental conditions, the MISPE methodology was validated using spiked samples. The linearity for cloxacillin was assessed within the limits of 0.05-1.5 µg L-1 and the recovery percentage was higher than 98% (RSD < 4%). The limits of detection and limits of quantification were 0.29 and 0.37 µg L-1 and 0.8 and 0.98 µg L-1 for drinking and river water, respectively. The selectivity of MIP against other ß-lactam antibiotics with similar structures (oxacillin, cefazoline, amoxicillin and penicillin V) was studied, obtaining a good recovery higher than 85% for all except cefazoline. The proposed MISPE-HPLC methodology was successfully applied for the detection of cloxacillin in drinking water from Canal de Isabel II (Madrid) and river water from the Manzanares River (Madrid).

4.
Environ Res ; 214(Pt 3): 114034, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35948144

RESUMO

Microplastic (MP) ingestion, along with accumulated plasticizers such as bisphenol A (BPA), bisphenol F (BPF), and bisphenol S (BPS), and phthalates represented by diethyl phthalate (DEP), dibutyl phthalate (DBP) and bis (2-ethylhexyl) phthalate (DEHP), were quantified in bivalves, fish, and holothurians collected from a coastal pristine area at the western Mediterranean Sea. MP ingestion in sediment-feeders holothurians (mean value 12.67 ± 7.31 MPs/individual) was statistically higher than ingestion in bivalves and fish (mean 4.83 ± 5.35 and 3 ± 4.44 MPs/individual, respectively). The main ingested polymers were polyethylene, polypropylene, and polystyrene. The levels of BPS, BPF, and DEHP were highest in bivalves' soft tissue; BPA and DBP had the highest levels in the holothurians' muscle. In addition, the levels of all plasticizers assessed were lowest in fish muscle; only BPA levels in fish were higher than in bivalves, with intermediate values between those of bivalves and holothurians. This study provides data on exposure to MPs and plasticizers of different species inhabiting Cabrera Marine Protected Area (MPA) and highlights the differences in MP ingestion and levels of plasticizers between species with different ecological characteristics and feeding strategies.


Assuntos
Bivalves , Dietilexilftalato , Ácidos Ftálicos , Animais , Compostos Benzidrílicos , Dibutilftalato , Ingestão de Alimentos , Peixes , Microplásticos , Fenóis , Plastificantes , Plásticos
5.
J Hazard Mater ; 424(Pt A): 127264, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34879544

RESUMO

The growing plastic production and its continuous use is a significant problem. In addition, aquaculture practices have experienced a considerable growth and plastic is widely used in these activities, hence plasticizers must be considered due to their potential ecotoxicological impacts on species. Mussels placed inside an Integrated Multi-Trophic Aquaculture (IMTA) system and at two control locations were employed to quantify the ingestion of anthropogenic particles and associated chemical plasticizers, such as bisphenol A (BPA) jointly to bisphenol F (BPF) and bisphenol S (BPS), and phthalates represented by diethyl phthalate (DEP), dibutyl phthalate (DBP) and bis(2-ethylhexyl) phthalate (DEHP). In addition, some metabolism and oxidative stress related parameters were measured in mussels' whole soft tissue. Anthropogenic particle ingestion of mussels increased over time at the three locations and the following order of abundance of pollutants was observed: BPA> BPF> DEHP> DBP> BPS> DEP. Even though no differences according to location were found for pollutants' occurrence, time trends were evidenced for BPA and DEHP. On the other hand, a location effect was observed for biomarkers with highest values detected in mussels located at the vicinities of the aquaculture facility. In addition, a reduced detoxification activity was observed over time parallel to BPA decrease.


Assuntos
Mytilus , Ácidos Ftálicos , Animais , Aquicultura , Monitoramento Biológico , Dibutilftalato , Ácidos Ftálicos/toxicidade , Plastificantes/toxicidade
6.
Talanta ; 126: 157-62, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24881547

RESUMO

A molecularly imprinted polymer-matrix solid-phase dispersion methodology for simultaneous determination of five steroids in goat milk samples was proposed. Factors affecting the extraction recovery such as sample/dispersant ratio and washing and elution solvents were investigated. The molecularly imprinted polymer used as dispersant in the matrix solid-phase dispersion procedure showed high affinity to steroids, and the obtained extracts were sufficiently cleaned to be directly analyzed. Analytical separation was performed by micellar electrokinetic chromatography using a capillary electrophoresis system equipped with a diode array detector. A background electrolyte composed of borate buffer (25mM, pH 9.3), sodium dodecyl sulfate (10mM) and acetonitrile (20%) was used. The developed MIP-MSPD methodology was applied for direct determination of testosterone (T), estrone (E1), 17ß-estradiol (17ß-E2), 17α-ethinylestradiol (EE2) and progesterone (P) in different goat milk samples. Mean recoveries obtained ranged from 81% to 110%, with relative standard deviations (RSD)≤12%. The molecularly imprinted polymer-matrix solid-phase dispersion method is fast, selective, cost-effective and environment-friendly compared with other pretreatment methods used for extraction of steroids in milk.


Assuntos
Leite/química , Impressão Molecular/métodos , Polímeros/química , Extração em Fase Sólida/métodos , Esteroides/análise , Acetonitrilas/química , Animais , Boratos/química , Soluções Tampão , Cromatografia Capilar Eletrocinética Micelar , Estradiol/análise , Estradiol/química , Estradiol/isolamento & purificação , Estrona/análise , Estrona/química , Estrona/isolamento & purificação , Etinilestradiol/análise , Etinilestradiol/química , Etinilestradiol/isolamento & purificação , Feminino , Cabras , Estrutura Molecular , Gravidez , Progesterona/análise , Progesterona/química , Progesterona/isolamento & purificação , Reprodutibilidade dos Testes , Dodecilsulfato de Sódio/química , Esteroides/química , Esteroides/isolamento & purificação , Testosterona/análise , Testosterona/química , Testosterona/isolamento & purificação
7.
Anal Chim Acta ; 638(2): 209-12, 2009 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-19327462

RESUMO

This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4x10(-3) mg L(-1). The detection limit was 3.17x10(-5) mg L(-1). Within- and between-day relative standard deviations RSD (n=5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1x10(-3) mg L(-1) digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.


Assuntos
Técnicas de Química Analítica/instrumentação , Digoxina/sangue , Membranas Artificiais , Impressão Molecular , Fenômenos Ópticos , Polímeros/química , Adsorção , Calibragem , Codeína/química , Digoxina/química , Fluorescência , Heroína/química , Humanos , Sensibilidade e Especificidade
8.
Anal Bioanal Chem ; 394(4): 963-70, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19132353

RESUMO

This work reports a comparative study of two automated flow-through fluorosensors for the determination of digoxin in serum samples: an immunosensor with an anti-digoxin polyclonal antibody as the reactive phase permanently immobilised on controlled-pore glass and a sensor with a selective reaction system based on a methacrylic molecularly imprinted polymer (MIP) synthesised by bulk polymerisation. The variables affecting the sensitivity and dynamic range of the sensors (e.g. the carrier and elution solutions, flow rates, pH and reagent concentrations) were optimized, and the binding characteristics of their reactive phases were compared in a competitive fluorescent assay. Digoxin was reproducibly determined by both sensors at the milligram per litre level (detection limit = 1.20 x 10(-3) mg L(-1) and RSD = 4-7% for the immunosensor; detection limit = 1.7 x 10(-5) mg L(-1) and RSD = 1-2% for the MIP sensor). No cross-reactivity with digoxin-related compounds was seen for either sensor at a digoxin/interferent ratio of 1:100. The lifetime of the immunosensor was about 50 immunoassays; its shelf life, when unused, is about 3 months. The lifetime of the MIP sensor was over 18 months. Both sensors were used to determine the digoxin concentration of human serum samples with satisfactory results.


Assuntos
Técnicas Biossensoriais/métodos , Digoxina/sangue , Fluorimunoensaio/métodos , Impressão Molecular , Ácidos Polimetacrílicos/química , Anticorpos/química , Reações Antígeno-Anticorpo , Análise de Injeção de Fluxo/métodos , Humanos , Ácidos Polimetacrílicos/síntese química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade